Smart battery protection and monitoring IC
M61040FP
9. Data Timing
ESTABLISHMENT DATA
Reset
Battery voltage output
Offset adjustment
Charge/discharge current detection
FET control
Multiplexer select
Conditioning circuit
Regulator
Over current control
Table 5.
ADDRESS
D5 D4 D3
000
001
010
011
100
101
DATA
D2 D1 D0
1 1 0
CONTENTS
Refer to table 6.
Refer to table 7.
Refer to table 8.
Refer to table 9.
Refer to table 10.
Refer to table 11.
1 1 1 Refer to table 12.
D2 D1 D0
Table 6 Battery voltage output
OUTPUT VOLTAGE
0
0
0
V1
0
0
1
V2
0
1
0
V3
0
1
1
V4
1
0
0
Connect to VIN_2
1
0
1
Connect to VIN_3
1
1
0
Connect to VIN_4
1
1
1
Connect to VIN_10
•V1 battery voltage output when system reset
DETAIL
Offset voltage output
Offset voltage output
Offset voltage output
Offset voltage output
Table 7 Offset voltage control section of discharge current monitor amplifier
OUTPUT
D2 D1 D0
Offset voltage value
0
0
0
No offset (0V)
0
0
1
1V
0
1
0
2.1V
0
1
1
3.1V
1
0
0
3.7V
1
0
1
1V
1
1
0
1V
1
1
1
1V
•No offset voltage when system reset
Mitsubishi Electric
(17/25)