Electrical Characteristics (Ta = 25°C)
Characteristics
Symbol
Test Condition
Gate leakage current
Gate−source breakdown voltage
Drain cut−off current
Drain−source breakdown voltage
Gate threshold voltage
Drain−source ON resistance
Forward transfer admittance
Input capacitance
Reverse transfer capacitance
Output capacitance
IGSS
V (BR) GSS
IDSS
V (BR) DSS
Vth
RDS (ON)
|Yfs|
Ciss
Crss
Coss
VGS = ±25 V, VDS = 0 V
ID = ±10 μA, VGS = 0 V
VDS = 600 V, VGS = 0 V
ID = 10 mA, VGS = 0 V
VDS = 10 V, ID = 1 mA
VGS = 10 V, ID = 1 A
VDS = 10 V, ID = 1 A
VDS = 10 V, VGS = 0 V, f = 1 MHz
Rise time
tr
Turn−on time
ton
Switching time
Fall time
tf
Turn−off time
Total gate charge (gate−source
plus gate−drain)
Gate−source charge
Gate−drain (“miller”) Charge
toff
Qg
Qgs
VDD ≈ 480 V, VGS = 10 V, ID = 2 A
Qgd
Source−Drain Ratings and Characteristics (Ta = 25°C)
Characteristics
Continuous drain reverse current
(Note 1)
Pulse drain reverse current
(Note 1)
Forward voltage (diode)
Reverse recovery time
Reverse recovery charge
Symbol
IDR
IDRP
IDRP
VDSF
trr
Qrr
Test Condition
—
t = 1 ms
t = 100 μs
IDR = 2 A, VGS = 0 V
IDR = 2 A, VGS = 0 V
dIDR / dt = 100 A / μs
Marking
2SK2846
Min Typ. Max Unit
—
—
±10
μA
±30 —
—
V
—
—
100
μA
600
—
—
V
2.0
—
4.0
V
—
4.2 5.0
Ω
0.8 1.7
—
S
— 380 —
—
40
—
pF
— 120 —
—
15
—
—
25
—
ns
—
20
—
—
80
—
—
9
—
—
5
—
nC
—
4
—
Min Typ. Max Unit
—
—
2
A
—
—
5
A
—
—
8
A
—
—
−1.5
V
— 1000 —
ns
—
3.5
—
μC
K2846
Note 4: A line under a Lot No. identifies the indication of product
Part No. (or abbreviation code)
Labels.
Not underlined: [[Pb]]/INCLUDES > MCV
Lot No.
Underlined: [[G]]/RoHS COMPATIBLE or [[G]]/RoHS [[Pb]]
Please contact your TOSHIBA sales representative for details as to
Note 4
environmental matters such as the RoHS compatibility of Product.
The RoHS is the Directive 2002/95/EC of the European Parliament
and of the Council of 27 January 2003 on the restriction of the use of
certain hazardous substances in electrical and electronic equipment.
2
2009-09-29