MASWSS0093
GaAs Broadband SPDT Switch
DC - 6.0 GHz
Electrical Specifications: TA = 25°C, Z0 = 50 Ω, VC = 0 V / 3 V, PIN = 0 dBm
Parameter
Insertion Loss
Isolation
Return Loss
IP2
IIP3
Input P-1dB
2nd Harmonic
3rd Harmonic
T-rise, T-fall
Test Conditions
2.4 GHz
5.3 GHz
5.8 GHz
2.4 GHz
5.3 GHz
5.8 GHz
DC - 6.0 GHz
Two Tone, +15 dBm/Tone, 5 MHz Spacing, >50 MHz
2.4 GHz, VC = 3.0 V
5.8 GHz, VC = 3.0 V
2.4 GHz, VC = 5.0 V
5.8 GHz, VC = 5.0 V
Two Tone, +15 dBm/Tone, 5 MHz Spacing, >50 MHz
2.4 GHz, VC = 3.0 V
5.8 GHz, VC = 3.0 V
2.4 GHz, VC = 5.0 V
5.8 GHz, VC = 5.0 V
2.4 GHz
5.3 GHz
5.8 GHz
2.4 GHz, PIN = +20 dBm
5.8 GHz, PIN = +20 dBm
2.4 GHz, PIN = +20 dBm
5.8 GHz, PIN = +20 dBm
10% to 90% RF and 90% to 10% RF
Units
dB
dB
dB
dB
dB
dB
dB
Min.
—
—
—
24
23
21
—
dBm
—
dBm
—
dBm
—
dBm
—
dBm
—
dBm
—
dBm
—
dBm
—
dBm
—
dBm
—
dBm
—
dBm
—
dBm
—
dBm
—
dBm
—
nS
—
Ton, Toff
50% control to 90% RF, and 50% control to 10% RF
nS
—
Transients
—
mV
—
Control Current
|VC| = 3 V
µA
—
Typ.
0.70
0.85
0.85
29
28
26
20
98
81
107
87
57
53
57
54
40
36
37
-72
-69
-85
-75
55
80
14
15
Rev. V2
Max.
1.05
1.20
1.20
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
25
Truth Table 6,7,8
Control V1 Control V2 RFC– RF1 RFC—RF2
1
0
On
Off
0
1
Off
On
5. For positive voltage control, external DC blocking
capacitors are required on all RF ports.
6. Differential voltage, V (state 1) - V (state 0), must be
+2.7 V minimum and must not exceed +5 V.
7. 0 = 0 ± 0.2 V, 1 = +2.9 V to +5 V.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
2
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions • North America Tel: 800.366.2266 / Fax: 978.366.2266
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macomtech.com for additional data sheets and product information.
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.