MT8816
Data Sheet
AC Electrical Characteristics† - Control and I/O Timings- Voltages are with respect to VDD = 5 V, VSS = 0 V, VEE = -7V, unless
otherwise stated.
Characteristics
Sym. Min. Typ.‡ Max. Units
Test Conditions
1 Control Input crosstalk to switch CXtalk
30
(for CS, DATA, STROBE,
Address)
mVpp
VIN=3 V squarewave;
RIN=1 kΩ, RL=10 kΩ.
See Appendix, Fig. A.6
2 Digital Input Capacitance
CDI
10
pF f=1 MHz
3 Switching Frequency
4 Setup Time DATA to STROBE
5 Hold Time DATA to STROBE
6 Setup Time Address to
STROBE
FO
tDS
10
tDH
10
tAS
10
20 MHz
ns RL= 1 kΩ, CL=50 pF ¿
ns RL= 1 kΩ, CL=50 pF ¿
ns RL= 1 kΩ, CL= 50pF ¿
7 Hold Time Address to STROBE
tAH
10
ns RL= 1 kΩ,
8 Setup Time CS to STROBE
tCSS
10
ns RL= 1 kΩ,
9 Hold Time CS to STROBE
tCSH 10
ns RL= 1 kΩ,
10 STROBE Pulse Width
tSPW 20
ns RL= 1 kΩ,
11 RESET Pulse Width
tRPW 40
ns RL= 1 kΩ,
12 STROBE to Switch Status Delay tS
40 100
ns RL= 1 kΩ,
13 DATA to Switch Status Delay
tD
50 100
ns RL= 1 kΩ,
14 RESET to Switch Status Delay
tR
35 100
ns RL= 1 kΩ,
† Timing is over recommended temperature range. See Fig. 3 for control and I/O timing details.
Digital Input rise time (tr) and fall time (tf) = 5 ns.
‡ Typical figures are at 25°C and are for design aid only; not guaranteed and not subject to production testing.
¿ Refer to Appendix, Fig. A.7 for test circuit.
CL=50 pF ¿
CL=50 pF ¿
CL=50 pF ¿
CL=50 pF ¿
CL=50 pF ¿
CL=50 pF ¿
CL=50 pF ¿
CL=50 pF ¿
7
Zarlink Semiconductor Inc.