AC/DC Open Frame
125 Watts
IFC125 Series
XPiQ inc.
Intelligent Design Quality Product
•
Active PFC - Meets EN61000-3-2, -3
•
Small Size 3.0” x 5.0” x 1.25”
•
Single, Triple & Quad Outputs
•
Overvoltage & Overcurrent Protection
•
Power Fail Detect
•
International Safety Approvals
Specification
Input
AC Input Voltage
Input Frequency
Power Factor
Inrush Current
Input Current
• 90-264 VAC
• 47-63 Hz
• 0.98 typical
• 24 A max at 100 VAC
• 0.8 A max at 240 VAC
1.8 A max at 100 VAC
Output
Output Voltage
•
Output Power
•
Minimum Load
•
Line/Load Regulation •
Ripple and Noise
•
Transient Response •
Temperature
•
Coefficient
Hold up Time
•
Overvoltage
•
Protection
Overcurrent
•
Protection
Remote Sense
•
See Table
125 Watts
5 W minimum load on any output
or combination of outputs required
to maintain regulation
See Table
±2% pk-pk maximum
> = 5 V out ±1% maximum
5% max deviation, recovering
to a 1% of final value in less than
500 µs after a 25% load change
0.04%/°C maximum
>28 ms minimum at full load
V1 & V2: 113% to 148% recycle input
to reset
All outputs 115% to 135% with
auto recovery
V1 only compensates for 0.5 V drop
Not Available on IFC125-31
General
Efficiency
Power Density
MTBF
Isolation Voltage
Signals
Size
Weight
• 83% typical
• 6.66 W/in3
• >220,000 hours per Bellcore
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• Power Good - On = Logic Hi
• 5.00” x 3.00” x 1.25”
• 312 grams approx.
Environmental
Operating
•
Temperature
Cooling
•
Humidity
•
Storage Temperature •
-25 °C to +70 °C derate linearly from
100% load at +70 °C to 50% load
at +50 °C
5 CFM forced air required for 125 W
5-95% RH, non-condensing
-40 °C to +85 °C
EMC & Safety
Safety Approvals
•
EMI/EMC
•
UL60950, CSA22.2: 60950 per cUL,
EN60950, CE mark LVD
Meets EN61000-3-2, -3
EN55022/CISPR22 Class B and FCC
Class B conducted
•
www.XPiQ.com
PH: 508 429.9883
•
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA