Maximal zulässiger Durchlassstrom
Max. Permissible Forward Current
LP; IF = f (T)
40
OHL01099
IF
30
TA
TS
20
10
TA temp. ambient
TS temp. solder point
0
0
20 40 60 80 ˚C 100
T
Zulässige Impulsbelastbarkeit IF = f (tp)
Permissible Pulse Handling Capability
Duty cycle D = parameter, TA = 25 °C
LS, LY, LG
10 4
OHL01162
IF mA
tP
D= tP
IF
T
T
10 3
5
0.1
0.2
10 2 0.5
5 DC
D= 0.005
0.01
0.02
0.05
10 1
10-5 10-4 10-3 10-2 10-1 100 s 101
tp
2006-01-01
LS 3341, LY 3341, LG 3341, LP 3341
Maximal zulässiger Durchlassstrom
Max. Permissible Forward Current
LS, LY, LG; IF = f (T)
50
OHL01105
IF
40
TA
TS
30
20
10
TA temp. ambient
TS temp. solder point
0
0
20
40 60 80 ˚C 100
T
Zulässige Impulsbelastbarkeit IF = f (tp)
Permissible Pulse Handling Capability
Duty cycle D = parameter, TA = 25 °C
LP
10 3
IF
mA
tP
D = tP
T
T
OHL01686
IF
D = 0.005
0.01
0.02
0.05
0.1
10 2 0.2
5 0.5
DC
10 1
10-5 10-4 10-3 10-2 10-1 100 s 101
tp
8