Doc No.:
Issued Date: Jun. 04, 2008
Model No.: M185B1-L02
Tentative
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Item
Symbol
Value
Unit
Note
Min.
Max.
Storage Temperature
TST
-20
60
ºC
(1)
Operating Ambient Temperature
TOP
0
50
ºC
(1), (2)
Shock (Non-Operating)
SNOP
-
Vibration (Non-Operating)
VNOP
-
50
G
1.5
G
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta ≦ 40 ºC).
.tw (b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
Note (2) The temperature of panel display surface area should be 0 ºC Min. and 60 ºC Max.
Relative Humidity (%RH)
100
m 90
80
.co 60
Operating Range
40
d 20
lc10
Storage Range
(3), (5)
(4), (5)
s -40
-20
0
20
40
60
80
Temperature (ºC)
.y Note (3) 50G,11ms, half sine wave, 1 time for ± X, ± Y, ± Z.
Note (4) 10 ~ 300 Hz, 10min/cycle, 3 cycles each X, Y, Z.
w Note (5) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough
so that the module would not be twisted or bent by the fixture.
wThe fixing condition is shown as below:
wAt Room Temperature
LCD Module
Side Mount Fixing Screw
Side Mount Fixing Screw
Stage
Gap=2mm
Bracket
5 / 25
Version 0.0