Product Specification
MF609A
5. Environmental condition:
5.1. EMC , surge and power- contact:
The splitter has to comply with EMC Requirements as per ITU K21, so the following
requirements must be taken into consideration:
No
Test
1 Lightning surge simulation
2 Power induction
3 Power contact
Test specification
1500V , 10/700µs , 200ms
600V , 1s
230V , 15 minute
Number of tests
10
5
1
5.2. Climatic condition:
5.2.1. Operating temperature:
Application
indoor
Low ambient temperature
-50C
High ambient temperature
+450C
(according to ETS 300 019, class 3.2)
5.2.2. Storage and transport:
Low ambient temperature
-400C
High ambient temperature
+850C
(according to ETS 300 019, transport: class 2.3, storage: class 1.2)
Data sheet subject to change without notice
RDPS-MF038(R0)01/23/2002
SHEET 10 OF 12