Output sequence (data format)
The output operation will start when the selected code is found. A burst of pulses, including the latched address and
command codes, is generated at the output REMO as long as a key is pressed. The format of the output pulse train is
given in Figs 2 and 3. The operation is terminated by releasing the key or if more than one key is pressed at the same
time. Once a sequence is started, the transmitted words will always be completed after the key is released.
The toggle bits T0 and T1 are incremented if the key is released for a minimum time tREL (see Fig.4).
The toggle bits remain unchanged within a multiple key-stroke sequence.
REF = reference time; T0 and T1 = toggle bits; S0, S1 and S2 = system address; A, B, C, D, E and F = command bits
(a) flashed mode: transmission with 2 toggle bits and 3 address bits, followed by 6 command bits (pulses are flashed).
(b) modulated mode: transmission with reference time, 1 toggle bit and 3 address bits, followed by 6 command bits (pulses are modulated).
Fig.2 Data format of REMO output; .
(1) Flashed pulse.
(2) Modulated pulse (tPW = (5 × tM) + tMH.
August 1982
Fig.3 REMO output waveform.