ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias ................... ā65Ā°C to +135Ā°C
Storage Temperature........................ ā65Ā°C to +150Ā°C
Voltage on any Pin with
Respect to VSS.................................... ā1V to +7V
D.C. Output Current ..............................................5mA
Lead Temperature
(Soldering, 10 seconds) .............................. 300Ā°C
RECOMMENDED OPERATING CONDITIONS
*COMMENT
Stresses above those listed under āAbsolute Maximum
Ratingsā may cause permanent damage to the device.
This is a stress rating only and the functional operation
of the device at these or any other conditions above
those indicated in the operational sections of this
speciļ¬cation is not implied. Exposure to absolute
maximum rating conditions for extended periods may
affect device reliability.
Temperature
Commercial
Industrial
Military
Min.
0Ā°C
ā40Ā°C
ā55Ā°C
Max.
+70Ā°C
+85Ā°C
+125Ā°C
3091 FM T06.1
Supply Voltage
X25128
X25128-2.7
Limits
5V Ā±10%
2.5V to 5.5V
3091 FM T07.2
D.C. OPERATING CHARACTERISTICS
Limits
Symbol
Parameter
ICC
VCC Supply Current (Active)
ISB
ILI
ILO
VlL(1)
VIH(1)
VOL1
VOH1
VOL2
VOH2
VCC Supply Current (Standby)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Min.
ā1
VCC x 0.7
VCC ā 0.8
VCC ā 0.3
Max. Units
Test Conditions
5
1
10
10
VCC x 0.3
VCC + 0.5
0.4
0.4
mA SCK = VCC x 0.1/VCC x 0.9 @ 2 MHz,
SO = Open, CS = VSS
ĀµA CS = VCC, VIN = VSS or VCC
ĀµA VIN = VSS to VCC
ĀµA VOUT = VSS to VCC
V
V
V VCC = 5V, IOL = 3mA
V VCC = 5V, IOH = -1.6mA
V VCC = 3V, IOL = 1.5mA
V VCC = 3V, IOH = -0.4mA
POWER-UP TIMING
Symbol
tPUR(3)
tPUW(3)
Parameter
Power-up to Read Operation
Power-up to Write Operation
CAPACITANCE TA = +25Ā°C, f = 1MHz, VCC = 5V
Min.
Max.
1
5
Units
ms
ms
3091 FM T09
Symbol
Test
Max.
Units
Conditions
COUT(2)
CIN(2)
Output Capacitance (SO)
Input Capacitance (SCK, SI, CS, WP, HOLD)
8
pF
6
pF
VOUT = 0V
VIN = 0V
Notes: (1) VIL min. and VIH max. are for reference only and are not tested.
(2) This parameter is periodically sampled and not 100% tested.
(3) tPUR and tPUW are the delays required from the time VCC is stable until the speciļ¬ed operation can be initiated. These
parameters are periodically sampled and not 100% tested.
3091 FM T10.1