ST95P02
AC MEASUREMENT CONDITIONS
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing
Reference Voltages
≤ 50ns
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
Note that Output Hi-Z is defined as the point where data
is no longer driven.
Figure 4. AC Testing Input Output Waveforms
0.8VCC
0.2VCC
0.7VCC
0.3VCC
AI00825
Table 3. Input Parameters (1) (TA = 25 °C, f = 1 MHz )
Symbol
Parameter
CIN
Input Capacitance (D)
CIN
Input Capacitance (other pins)
tLPF
Input Signal Pulse Width
Note: 1. Sampled only, not 100% tested.
Min
Max
Unit
8
pF
6
pF
10
ns
Table 4. DC Characteristics
(TA = 0 to 70°C or –40 to 85°C; VCC = 3V to 5.5V)
Symbol
ILI
ILO
Parameter
Input Leakage Current
Output Leakage Current
ICC
VCC Supply Current (Active)
Test Condition
Min
Max
Unit
2
µA
±2
µA
C = 0.1 VCC/0.9 VCC ,
@ 2 MHz, Q = Open
2
mA
ICC1
VCC Supply Current (Standby)
VIL
Input Low Voltage
VIH
Input High Voltage
VOL
Output Low Voltage
VOH
Output High Voltage
S = VCC, VIN = VSS or VCC,
VCC = 5.5V
50
µA
S = VCC, VIN = VSS or VCC,
VCC = 3V
10
µA
– 0.3
0.3 VCC
V
0.7 VCC
VCC + 1
V
IOL = 2mA
0.2 VCC
V
IOH = –2mA
0.8 VCC
V
4/16