DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PM5344 View Datasheet(PDF) - PMC-Sierra

Part Name
Description
Manufacturer
PM5344 Datasheet PDF : 212 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
DATA SHEET
PMC-930531
ISSUE 6
PM5344 SPTX
SONET/SDH PATH TERMINATING TRANSCEIVER
· Detects path FERF alarm.
· Extracts and serializes the entire path overhead from the three STS-1 (AU3)
or single STS-3c (AU4) stream. Identifies the positions of the path overhead
bytes in the serialized streams.
· Extracts the path signal label (C2) byte into an internal register and detects
for path signal label unstable and for signal label mismatch with the expected
signal label that is downloaded by the microprocessor.
· Extracts the 64 byte or 16 byte path trace (J1) message into an internal
register bank.
· Detects for unstable path trace message and mismatch with the expected
path trace message that is downloaded by the microprocessor.
· Detects received path BIP-8 and counts received path BIP-8 errors for
performance monitoring purposes. Path BIP-8 errors are also available on an
output pin. BIP-8 errors are selectable to be treated on a bit basis or block
basis.
· Counts received path far end block errors (FEBEs) for performance
monitoring purposes.
· Extracts the three STS-1 (AU3) payloads or single STS-3c (AU4) payload and
presents it on a byte serial bus.
· Supports Telecombus interfaces by indicating the location of the STS
identification byte (C1), the path trace byte(s) (J1), the first tributary overhead
byte(s) (V1), and all synchronous payload envelope bytes in the byte serial
stream. Also generates bus parity.
· Accomodates phase and frequency differences between the receive stream
and the DROP bus via pointer adjustments in the DROP bus.
· Supports tandem connection origination applications by sourcing a new
tandem path maintenance byte (Z5) reporting the received BIP-8 errors and
the data link message and correcting subsequent path BIP-8 bytes (B3) to
reflect the change in Z5.
· Supports tandem connection termination applications by accumulating the
incoming error count (IEC) and extracting the tandem connection data link
carried in the tandem path maintenance byte (Z5).
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE 2

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]