Electrical Characteristics: (TC = +25°C unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Peak Blocking Current (Either Direction) IDRM VDRM = 50V, TJ = +100°C, Gate Open – – 2.0 mA
On–State Voltage (Either Direction)
Gate Trigger Current, Continuous DC
All Modes
VTM ITM = 14A Peak
IGT
Main Terminal Voltage = 12V, RL = 100Ω
– 1.3 1.8 V
– – 40 mA
MT2 (+), G (+); MT2 (–), G (–)
Gate Trigger Voltage, Continuous DC
– – 50 mA
VGT Main Terminal Voltage = 12V, RL = 100Ω – 0.9 2.0 V
VGD Main Terminal Voltage = 50V, RL = 100Ω, 0.2 – – V
TJ = +100°C
Holding Current (Either Direction)
IH Main Terminal Voltage = 12V,
Gate Open, Initiating Current = 100mA
– – 30 mA
Turn–On Time
Blocking Voltage Application Rate
at Commutation
ton ITM = 14A, IGT = 100mA
dv/dt VDRM = 50V, TJ = +75°C, Gate Open
– 1.5 – µs
– 5.0 – V/µs
.431
(10.98
Max
Gate
.855
(21.7)
Max
.453
(111.5)
Max
MT1
.125 (3.17) Max
MT2
10–32 UNF–2A