Micrel
SY100EL90V
AC ELECTRICAL CHARACTERISTICS
ECL: VEE = –4.2V to –5.5V; LVECL: VEE = –3.0V to –3.8V; PECL: VCC = +4.2V to +5.5V; LVPECL: VCC = +3.0V to +3.8V
TA = –40°C
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
tPLH
Propagation Delay Diff. 390 — 590 410 — 610 420 — 620 460 — 660 ps
tPHL
D to Q
S.E. 340 — 640 360 — 660 370 — 670 410 — 710
tskew
Within-Device Skew(1)
Output-to-Output
Part-to-Part (Diff.)
Duty Cycle (Diff.)
— 20 100 —
— — 200 —
— 25 — —
20 100 —
— 200 —
25 — —
20 100 —
— 200 —
25 — —
20 100 ps
— 200
25 —
VPP
Minimum Input Swing(2) 150 — — 150 — — 150 — — 150 — — mV
VCMR
Common Mode Range(3) — — –0.4 —
— –0.4 —
— –0.4 —
— –0.4 V
tr
Output Rise/Fall Times Q 230 — 500 230 — 500 230 — 500 230 — 500 ps
tf
(20% to 80%)
NOTES:
1. Skew is measured between outputs under identical transitions.
2. Minimum input swing for which AC parameters are guaranteed. The device will function reliably with differential inputs down to 100mV.
3. The CMR range is referenced to the most positive side of the differential input signal. Normal operation is obtained if the HIGH level falls within the specified
range and the peak-to-peak voltage lies between VPP min. and 1V. VCMR min. depends on VEE, VPP and temperature at VPP <500mV and –40˚C, VCMR
is VEE+1.3V; and for 0–85˚C, VCMR is VEE+1.2V. At VPP ≥ 500mV and –40˚C, VCMR is VEE+1.5V; and for 0–85˚C, VCMR is VEE+1.4V.
PRODUCT ORDERING CODE
Ordering
Code
SY100EL90VZC
SY100EL90VZCTR
Package
Type
Z20-1
Z20-1
Operating
Range
Commercial
Commercial
3