B43510, B43520
Compact 85 °C
Specifications and characteristics in brief
Rated voltage VR
Surge voltage VS
Rated capacitance CR
Capacitance tolerance
Leakage current Ileak
(5 min, 20 °C)
385 ... 500 V DC
1.1 VR
390 ... 2700 µF
±20% M
Self-inductance ESL Approx. 20 nH
Useful life
Requirements:
85 °C; VR; IAC,R
40 °C; VR; 1.1 IAC,R
Voltage endurance test
85 °C; VR
Vibration resistance
test
> 5000 h
∆C/C ≤ ±30% of initial value
> 250000 h ESR ≤ 3 times initial specified limit
Ileak
≤ initial specified limit
Post test requirements:
2000 h
∆C/C
ESR
Ileak
≤ ±10% of initial value
≤ 1.3 times initial specified limit
≤ initial specified limit
To IEC 60068-2-6, test Fc:
Displacement amplitude 0.35 mm, frequency range 10 ... 55 Hz,
acceleration max. 5 g, duration 3 × 2 h.
Capacitor mounted by its body which is rigidly clamped to the work
surface.
Characteristics at low
temperature
Max. impedance
ratio
VR
≤ 400 V 420 ... 450 V 500 V
at 100 Hz
Z -25 °C / Z 20 °C 4
7
7
Z -40 °C / Z 20 °C 7
14
20
IEC climatic category
Detail specification
Sectional specification
To IEC 60068-1:
VR ≤ 400 V DC: 40/085/56 (40 °C/+85 °C/56 days damp heat test)
VR > 400 V DC: 25/085/56 (25 °C/+85 °C/56 days damp heat test)
The capacitors can be operated in the temperature range of
40 °C to +85 °C but the impedance at 40 °C should be taken into
consideration.
Similar to CECC 30301-805
IEC 60384-4
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 19