DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX1205CMH View Datasheet(PDF) - Maxim Integrated

Part Name
Description
Manufacturer
MAX1205CMH Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
+5V Single-Supply, 1Msps, 14-Bit
Self-Calibrating ADC
TIMING CHARACTERISTICS
(AVDD = +5V ±5%, DVDD = DRVDD = +3.3V, fCLK = 2.048MHz, TA = TMIN to TMAX, unless otherwise noted. Typical values are at
TA = +25°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Conversion Time
Clock Period
Clock High Time
Clock Low Time
tCONV
tCLK
tCH
tCL
4 / fSAMPLE
ns
488
ns
187
244
301
ns
187
244
301
ns
Acquisition Time
tACQ
tCLK / 2
ns
Output Delay
DAV Pulse Width
CLK-to-DAV Rising Edge
Data Access Time
Bus Relinquish Time
tOD
tDAV
tS
tAC
tREL
CL = 20pF
70
150
ns
1 / fCLK
ns
65
145
ns
16
75
ns
16
75
ns
Calibration Time
tCAL
ST_CAL = 1, Figure 8
17,400
fCLK
cycles
DIGITAL INPUTS AND OUTPUTS
(AVDD = +5V ±5%, DVDD = DRVDD = +3.3V, TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Input Low Voltage
VIL
0.8
V
Input High Voltage
VIH
DVDD
- 0.8
V
Input Capacitance
CLK Input Low Voltage
CLK Input High Voltage
CLKVIL
CLKVIH
4
pF
0.8
V
AVDD
- 0.8
V
CLK Input Capacitance
Digital Input Current
Clock Input Current
Output Low Voltage
Output High Voltage
CCLK
IIN_
ICLK
VOL
VOH
VIN_ = 0 or DVDD
ISINK = 1.6mA
ISOURCE = 200µA
9
pF
±0.1 ±10
µA
-10
±1
+10
µA
70
400
mV
DVDD DVDD
- 0.4 - 0.03
V
Three-State Leakage Current
ILEAKAGE
Three-State Output Capacitance COUT
±0.1 ±10
µA
3.5
pF
Note 1: Reference inputs driven by operational amplifiers for Kelvin-sensed operation.
Note 2: For unipolar mode, the analog input voltage VINP must be within 0V and VREF, VINN = VREF / 2; where VREF = VRFPS - VRFNS.
For differential mode, the analog inputs INP and INN must be within 0V and VREF; where VREF = VRFPS - VRFNS. The com-
mon mode of the inputs INP and INN is VREF / 2.
Note 3: Minimum and maximum parameters are not tested. Guaranteed by design.
Note 4: RI varies inversely with sample rate.
Note 5: Calibration remains valid for temperature changes within ±20°C and power-supply variations ±5%.
Note 6: All AC specifications are shown for the differential mode.
4 _______________________________________________________________________________________

Share Link: 