AC CHARACTERISTICS (tR = tF = 2.5 ns; RL = 500 Ω)
Limits
Symbol
Parameter
Waveform
VCC = 3.0 V to 3.6 V
CL = 50 pF
Min
Max
TA = –40°C to +85°C
VCC = 2.7 V
CL = 50 pF
Min
Max
VCC = 2.5 V +0.2
CL = 30 pF
Min
Max
Unit
tPLH
Propagation Delay
1
tPHL
Input to Output
tPZH
Output Enable Time to
2
tPZL
High and Low Level
tPHZ
Output Disable Time From
2
tPLZ
High and Low Level
tOSHL
tOSLH
Output–to–Output Skew
(Note 3.)
1.5
6.5
1.5
7.5
1.5
7.8
ns
1.5
6.5
1.5
7.5
1.5
7.8
1.5
8.0
1.5
9.0
1.5
10
ns
1.5
8.0
1.5
9.0
1.5
10
1.5
7.0
1.5
8.0
1.5
8.4
ns
1.5
7.0
1.5
8.0
1.5
8.4
1.0
ns
1.0
3. Skew is defined as the absolute value of the difference between the actual propagation delay for any two separate outputs of the same device.
The specification applies to any outputs switching in the same direction, either HIGH–to–LOW (tOSHL) or LOW–to–HIGH (tOSLH); parameter
guaranteed by design.
DYNAMIC SWITCHING CHARACTERISTICS
Symbol
Characteristic
Condition
TA = +25°C
Min Typ Max Unit
VOLP
Dynamic LOW Peak Voltage (Note 4.) VCC = 3.3 V, CL = 50 pF, VIH = 3.3 V, VIL = 0 V
0.8
V
VCC = 2.5 V, CL = 30 pF, VIH = 2.5 V, VIL = 0 V
0.6
VOLV
Dynamic LOW Valley Voltage (Note 4.) VCC = 3.3 V, CL = 50 pF, VIH = 3.3 V, VIL = 0 V
–0.8
V
VCC = 2.5 V, CL = 30 pF, VIH = 2.5 V, VIL = 0 V
–0.6
4. Number of outputs defined as “n”. Measured with “n–1” outputs switching from HIGH–to–LOW or LOW–to–HIGH. The remaining output is
measured in the LOW state.
CAPACITIVE CHARACTERISTICS
Symbol
Parameter
Condition
Typical
Unit
CIN
Input Capacitance
VCC = 3.3 V, VI = 0 V or VCC
7
pF
COUT
Output Capacitance
VCC = 3.3 V, VI = 0 V or VCC
8
pF
CPD
Power Dissipation Capacitance
10 MHz, VCC = 3.3 V, VI = 0 V or VCC
25
pF
http://onsemi.com