Industrial Version
PLCC DC Electrical Characteristics (Note 7)
VEE = −4.2V to −5.7V, VCC = VCCA = GND, TC = −40°C to +85°C
Symbol
Parameter
TC = −40°C
Min
Max
TC = 0°C to +85°C
Min
Max
Units
Conditions
VOH
VOL
VOHC
VOLC
VIH
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
−1085
−1830
−1095
−1170
−870
−1575
−1565
−870
−1025
−1830
−1035
−1165
−870
−1620
−1610
−870
mV VIN =VIH (Max)
Loading with
mV or VIL(Min)
50Ω to −2.0V
mV VIN = VIH (Min)
Loading with
mV or VIL(Max)
50Ω to −2.0V
mV Guaranteed HIGH Signal
for All Inputs
VIL
Input LOW Voltage
−1830 −1480 −1830 −1475
mV Guaranteed LOW Signal
for All Inputs
IIL
Input LOW Current
0.50
0.50
µA VIN = VIL (Min)
IIH
Input HIGH Current
I0X–I3X
340
340
µA VIN = VIH (Max)
S0, S1, E
300
300
IEE
Power Supply Current
−75
−35
−75
−39
mA Inputs Open
Note 7: The specified limits represent the “worst case” value for the parameter. Since these values normally occur at the temperature extremes, additional
noise immunity and guardbanding can be achieved by decreasing the allowable system operating ranges. Conditions for testing shown in the tables are cho-
sen to guarantee operation under “worst case” conditions.
PLCC AC Electrical Characteristics
VEE = −4.2V to −5.7V, VCC = VCCA = GND
Symbol
Parameter
TC = −40°C
Min
Max
TC = +25°C
Min
Max
TC = +85°C
Min
Max
Units
tPLH
Propagation Delay
tPHL
I0x–I3x to Output
0.40
1.30
0.45
1.30
0.45
1.40
ns
tPLH
Propagation Delay
tPHL
S0, S1 to Output
0.70
2.20
0.90
2.20
1.00
2.40
ns
tPLH
Propagation Delay
tPHL
E to Output
0.65
2.10
0.65
2.10
0.75
2.20
ns
tTLH
Transition Time
tTHL
20% to 80%, 80% to 20%
0.20
1.60
0.35
1.10
0.35
1.10
ns
Note 8: The propagation delay specified is for single output switching. Delays may vary up to 300 ps with multiple outputs switching.
Conditions
Figures 1, 2
(Note 8)
Figures 1, 2
5
www.fairchildsemi.com