Version
Page
:1
: 6 /20
3. Electrical characteristics
a. Typical operating conditions (GND=AVss=0V, Note 4 )
Item
Symbol
Min.
Typ.
Max.
Unit
Remark
VCC
3
5
5.2
V
AVDD
4.8
5
5.2
V
Power supply
VGH
14.3
15
15.7
V
VGL
-10.5
-10
-9.5
V
Video signal
amplitude
(VR,VG,VB)
ViA
ViAC
ViDC
0.4
-
AVDD-0.4
V
-
3
-
V
-
AVDD/2
-
V
Note 1
AC component
DC component
VCOM
VCAC
3.5
5.6
6.5
Vp-p AC component, Note 2
VCDC
1.4
1.7
2.0
V
DC component
Input H Level
VIH
0.8 VCC
-
signal
VCC
V
Note 3
voltage L Level
VIL
0
-
0.2 VCC
V
Note 1: Refer to Fig.4- (a).
Note 2: The brightness of LCD panel could be changed by adjusting the AC component of
VCOM.
Note 3: STHL, STHR, OEH, L/R, CPH1~CPH3, STVR, STVL, OEV, CKV, U/D.
Note 4: Be sure to apply GND, VCC and VGL to the LCD first, and then apply VGH.
b. Current consumption (GND=AVss=0V)
Parameter Symbol Condition
Min.
Typ.
Max.
Unit
Remark
Current
for
driver
IGH
VGH=15V
-
IGL
VGL=-10V
-
ICC
VCC=5V
-
0.20
0.5
mA
0.80
1.5
mA
3.0
6.0
mA
IDD
AVDD=5V
-
17.0
30
mA
c. Backlight driving conditions
Parameter
Symbol
Min.
Typ.
Max.
Unit
Remark
Lamp voltage
VL
Lamp current
IL
Frequency
FL
Lamp starting voltage
VS
-
560
620
Vrms
-
6
7
mArms
-
60
80
kHz
Note 4
-
-
900
Vrms
Note 1,5
-
-
-
Vrms
Note 2,5
-
-
1,100
Vrms
Note 3,5
Lamp life time
10,000
-
-
Hr
Note 6
Note 1: Ta = 25℃.
Note 2: Ta = 0℃.
Note 3: Ta = -30℃.
Note 4: The lamp frequency should be selected as different as possible from display
horizontal synchronous signal to avoid interference.
Note 5: For starting the backlight unit, the output voltage of DC/AC’s transformer should be larger
than the maximum lamp starting voltage.
Note 6: The” Lamp life time” is defined as the module brightness decrease to 50% original
brightness at Ta=25℃ , IL=6mA.
ALL RIGHTS STRICTLY RESERVED. ANY PORTION OF THIS PAPER SHALL NOT BE REPRODUCED, COPIED, OR