Surge arrester
2-electrode arrester
B88069X2990T502
A81-A600XG
Features
Standard size
Very fast response time
High current rating
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
Applications
Line protection
Consumer electronics
Electrical specifications
DC spark-over voltage 1) 2)
Impulse spark-over voltage
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
Service life
10 operations
1 operation
10 operations [5× (+) & 5× (–)]
1 operation
1 operation
50 Hz, 1 s
50 Hz, 0.18 s (9 cycles)
8/20 µs
8/20 µs
10/350 µs
Insulation resistance at 100 Vdc
Capacitance at 1 MHz
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, blue positive
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
600
V
± 20
%
< 1100
V
< 950
V
< 1400
V
< 1100
V
20
A
100
A
20
kA
25
kA
2.5
kA
> 10
GΩ
< 1.5
pF
~ 10
V
~ 0.5
A
~ 60
V
~ 1.5
g
-40 ... +90
°C
40/ 90/ 21
600 YY O
600 - Nominal voltage
YY
- Year of production
O
- Non radioactive
KB PD AB E / KB PD AB PM
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 4
Issue 03 / 2009-11-12