ABSOLUTE MAXIMUM RATINGS
Supply voltage, V+ referenced to V-
Supply voltage, VS referenced to V-
Differential input voltage range
Power dissipation
Operating temperature range SAL, PAL, SCL, PCL packages
DA, DC packages
Storage temperature range
Lead temperature, 10 seconds
CAUTION: ESD Sensitive Device. Use static control procedures in ESD controlled environment.
-0.3V to +10.6V
±5.3V
-0.3V to +0.3V
600mW
0°C to +70°C
-55°C to +125°C
-65°C to +150°C
+260°C
OPERATING ELECTRICAL CHARACTERISTICS
TA = 25°C V+ = +5.0V unless otherwise specified
Parameter
Drain to Source Voltage 1
Symbol
V+
ALD1121E
Min Typ
Max
10.0
ALD1123E
Min
Typ
Max
10.0
Initial Threshold Voltage 2
Vt i
0.990 1.000 1.010 0.990 1.000 1.010
E-trim Vt Range
Vt
1.000
3.000 1.000
3.000
Drain - Gate Connected
TCVDS
-1.6
-1.6
Voltage Tempco
-0.3
-0.3
0.0
0.0
+2.7
+2.7
Initial Offset Voltage 3
VOS i
1
5
1
5
Unit
V
V
V
mV/°C
mV/°C
mV/°C
mV/°C
mV
Test
Conditions
IDS = 1µA TA = 21°C
ID = 5µA
ID = 50µA
ID = 68µA
ID = 500µA
Tempco of VOS
TCVOS
Differential Threshold Voltage 4 DV t
5
2.000
5
µV/°C
2.000 V
VDS1 = VDS2
Tempco of Differential
Threshold Voltage 4
TCDV t
0.033
0.033
mV/°C
Long Term Drift
∆Vt /∆t
-0.02 -0.05
-0.02 -0.05 mV
1000 Hours
Long Term Drift Match
∆Vt /∆t
-5
-5
µV
1000 Hours
Drain Source On Current
IDS(ON)
3.0
3.0
mA
VG =VD = 5V VS = 0V
Vt = 1.0
Drain Source On Current 4
IDS(ON)
0.8
0.8
mA
VG =VD = 5V VS = 0V
Vt = 3.0
Initial Zero Tempco Voltage 3 VZTC i
1.52
1.52
V
Vt = 1.000V
Zero Tempco Current
IZTC
68
68
µA
Initial On-Resistance 3
RON i
500
500
Ω
VGS ¡= 5V VDS = 0.1V
On-Resistance Match
∆RON
0.5
0.5
%
NOTES:
1. V+ must be the most positive supply rail and V- must be at the most negative supply rail. Source terminals other than those labeled as V- can be at
any voltage between V- and V+.
2. Initial Threshold Voltage is set at the factory. If no EPAD Vt trimming is intended by user, then this is also the final or permanent threshold voltage
value.
3. Initial and Final values are the same unless deliberately changed by user.
4. These parameters apply only when Vt of one or more of the devices are to be changed by user.
ALD1121E/ALD1123E
Advanced Linear Devices
3 of 14