ELECTRICAL SPECIFICATIONS
At TA = +25°C, +VIN = 15VDC, and IOUT = ±15mA unless otherwise noted.
PARAMETER
CONDITIONS
INPUT
Rated Voltage
Voltage Range
Input Current
Ripple Current
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Voltage
Voltage Accuracy
Rated Current
Current Range
Line Regulation
Load Regulation
Ripple Voltage
TEMPERATURE
Specification
Operating
Storage
IOUT = ±3mA
IOUT = ±33mA
IOUT = ±33mA
60s, 60Hz
VISO = 240VAC, 60Hz
10VDC ¯ VIN ¯ 18VDC
±3mA ¯ IOUT ¯ ±33mA
IOUT = ±3mA
IOUT = ±33mA
ABSOLUTE MAXIMUM RATINGS
Input Voltage...................................................................18VDC
Output Current..............................................................±150mA
Output Short-Circuit Duration...................................Continuous
MIN
10
2000
5000
0
–25
–55
–65
TYP
15
25
10
10
12
±15
±15
1.08
35
10
MAX
18
150
2
±5
±100
80
+85
+125
+150
UNITS
VDC
VDC
mA
mA
mAp-p
VDC
Vpk
GΩ
pF
µA
VDC
%
mA
mA
V/V
mV/mA
mVp-p
mVp-p
°C
°C
°C
ORDERING INFORMATION
PWR 70 /H
Device Family
PWR indicates DC/DC converter
Model Number
Reliability Screening
No designator indicates standard manufacturing processing
6
4
Equal Load
2
0
–2
–4
–6
0
Varying Load
(One output
constant 15mA load,
other output vary current.)
10 20 30 40 50
Output Current (mA)
FIGURE 1. Load Regulation.
2
1
0
±3mA Load
±30mA Load
–1
–2
–65 –35 –5 25 55 85 115 145
Ambient Temperature (°C)
FIGURE 2. Temperature Drift.
The information provided herein is believed to be reliable; however, C&D Technologies assumes no responsibility for inaccuracies or omissions. C&D Technologies assumes no responsibility for
the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any
of the circuits described herein are implied or granted to any third party. C&D Technologies does not authorize or warrant any C&D Technologies product for use in life support devices/systems
or in aircraft control applications. C&D Technologies, Iso-ThermoFlex and T.E.A.M. Q are trademarks of C&D Technologies Corporation.