CLP270M
Tables 1 to 6 summarize the surge needs defined by Bellcore regarding both lightning and AC power fault.
In case of first level test, the equipment under test shall be operating after the surge. For the second level
tests, the equipment under test may be damaged, but no fire or electrical safety hazard may occur.
3.2. First level lightning surge:
3.2.1. ringing mode
Fig. 10: Lightning simulation test.
I1
2/10 µs
GENERATOR
+/- 2.5 kV
(500 A)
4
Rsense
TIPL
TIPS
1/2 CLP270M
GND
Rp
V1
Lightning phenomena are the most common surge causes. The purpose of this test is to check the
behavior of the CLP270M against these lightning strikes.
Fig. 11: CLP270M response to a positive surge.
Fig. 12 : CLP270M response to a negative surge.
Figures 11 and 12 show that the remaining overvoltage does not exceed +/- 500 V. The CLP270M
Fig. 13: Lightning test in speech mode.
2/10 µs
GENERATOR
+/- 5 kV
(500 A)
I1
4
Rsense
50
I2
Rp
SLIC
TIPL
TIPS
1/2 CLP270M
GND
V1
-48V
V2
LCP15 11D
11/24