CXA3572R
Item
Symbol
Serial data
setting (HEX)
Measurement conditions
Min. Typ. Max. Unit
White limiter
variable amount
VWL
Set CONT = FFh, input SG2 (0.2Vp-p)
to TP22, measure the non-inverted
white limit level, and obtain the
0.3 0.6 1.0 V
difference from the output DC voltage.
Black level
difference between ∆VB
R, G and B
Measure the non-inverted black level
at TP8, TP10 and TP12, and obtain
the maximum and minimum
—
difference between these values.
— 300 mV
RGB and PSIG
output DC voltage
Vc
Measure the output DC level
(average voltage) at TP8, TP10,
TP12 and TP14.
5.8 6.0 6.2 V
DC voltage
difference between ∆Vc
RGB and PSIG
Measure the output average voltage
difference at TP8, TP10 and TP14
relative to the output average
—
voltage at TP12.
— 300 mV
VPB1
PSIG-BRT variable
amount
VPB2
PSIG-BRT
00h Assume the PSIG output amplitude
when PSIG-BRT = 00h and 7Fh as
PSIG-BRT VPB1 and VPB2, respectively.
7Fh
8.5 10.0
1.0 2.0
—
Vp-p
—
USER-BRT
variable amount
∆UB1
∆UB2
U-BRT Measure the non-inverted black level
00h at TP12 when U-BRT = 00h and FFh 4.5 4.8 —
and assume the difference from the
V
U-BRT average voltage as ∆UB1 and ∆UB2, 1.4 2.0 2.5
FFh respectively.
Level difference
between PSIG-BLK ∆VBB
and BLK-LIM
SLWD
1
Set BLK-LIM = 00h and measure
the difference between the inverted —
and non-inverted black level at TP12
and TP14.
— 300 mV
HUE variable
amount R
HUE variable
amount B
Set U-BRT = 80h, CONT = 80h,
∆HUR1 HUE 00h COLOR = 40h, input SG4 (56mVp-p) 1.5 3
to TP23, input SG4 (100mVp-p) to
TP24, and assume the amplitude at
∆HUR2 HUE 3Fh TP8 when HUE = 80h, 00h and 3Fh — –5
as VB1, VB2 and VB3.
Similarly, assume the amplitude at
∆HUB1 HUE 00h TP10 as VR1, VR2 and VR3.
∆HUR1 = 20 log (VR2/VR1)
— –5
∆HUR2 = 20 log (VR2/VR1)
∆HUB2
HUE 3Fh
∆HUB1 = 20 log (VB2/VB1)
∆HUB2 = 20 log (VB2/VB1)
1.5 3
—
–2
dB
–2
—
Picture variable
amount
GP1
GP2
PIC-G Set CONT = 80h, input SG3 to
00h TP22, and measure the TP12
–2.5 0
amplitude at f0 relative to the TP12
PIC-G amplitude at 100kHz when PIC-G =
1Fh 00h and 1Fh, respectively.
9
12
2.5
dB
—
Color variable
amount
GC1
GC2
Input SG4 (160mVp-p) to TP23 and
COLOR TP24, and assume the output
—
00h amplitude at TP8 and TP10 when
— –20
COLOR = 00h, 40h and 50h as V1,
dB
COLOR
50h
V2 and V3, respectively.
GC1 = 20 log (V1/V2)
GC2 = 20 log (V3/V2)
0.5 — —
– 15 –