EDGE HIGH-PERFORMANCE PRODUCTS
AC Characteristics
Edge118
Parameter
Propagation Delay
IN / IN* to OUT / OUT* (Notes 1, 5)
Channel-to-Channel Skew (Note 6)
Maximum Operating Frequency (Notes 1, 2, 3, 4)
Minimum Pulse Width (Notes 1, 2, 3, 4)
Output Rise and Fall Times (Notes 1, 4)
20% - 80%, 50Ω Load
10% - 90%, 50Ω Load
Jitter (Notes 1, 4)
Peak-to-Peak
∆Tpd vs. Duty Cycle, T = 100 ns (Notes 1, 4)
3.0% <= Duty Cycle <= 97%
0.5% <= Duty Cycle <= 99.5%
∆Tpd vs. Frequency (Notes 1, 4)
10 MHz <= Frequency <= 1.0 GHz
Temperature Coefficient (Notes 1, 4)
Symbol
Tpd
Fmax
PW min
Tr / Tf
Tr / Tf
∆Tpd
∆Tpd
∆Tpd
∆Tpd
Min
450
1000
Typ
550
<25
>1200
400
260
400
<.1
<10
<25
<30
1
Max
Units
650
ps
100
ps
MHz
500
ps
400
ps
500
ps
1
ps
ps
ps
ps
ps / ˚ C
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Measured in a terminated 50Ω transmission line environment.
And still maintain 80% amplitude.
And still maintain a propagation delay variation (measured at the differential crossing points) of
TPD ± 30 ps.
This parameter is guaranteed by characterization. It is not production tested against the
specification limit.
This parameter is guaranteed by design and characterization. It is production tested against
tester limits of Tpd = 550 ps ± 200 ps.
This parameter is guaranteed by design and characterization. It is production tested against
a tester limit of 160 ps.
2000 Semtech Corp.
10