NXP Semiconductors
KTY83 series
Silicon temperature sensors
8
∆T
(K)
4
0
−4
KTY83/151
KTY83/120
mgg693
KTY83/110
/121
/122
12
Isen(cont)
(mA)
8
4
mgg706
−8
−50
0
50
100
150
Tamb (°C)
Fig 1. Maximum expected temperature error (∆T)
3
R
(kΩ)
2
1
175 °C
150 °C
125 °C
100 °C
75 °C
50 °C
25 °C
0 °C
−25 °C
−55 °C
mgg697
0
−50
0
50
100
150
200
Tamb (°C)
Fig 2. Maximum operating current for safe operation
20
∆R
(Ω)
10
mgg707
0
0
10−1
1
Isen(cont) (mA)
10
−10
0
1
Isen(cont) (mA)
2
Fig 3.
To keep the temperature error low, an operating current
of Isen(cont) = 1 mA is recommended for temperatures
above 100 °C
Sensor resistance as a function of operating
current
Tamb = 25 °C
Fig 4. Deviation of sensor resistance as a function of
operating current in still liquid
KTY83_SER_6
Product data sheet
Rev. 06 — 4 April 2008
© NXP B.V. 2008. All rights reserved.
7 of 10