LH1502, LH1512
1 Form A/B, C
Absolute Maximum Ratings TA=25°C
Stresses in excess of the Absolute Maximum Ratings
can cause permanent damage to the device. These are
absolute stress ratings only. Functional operation of the
device is not implied at these or any other conditions in
excess of those given in the operational sections of this
document. Exposure to Absolute Maximum Ratings for
extended periods of time can adversely affect reliability.
Parameter
Symbol Test Conditions
LH1502
LH1512
Ambient Operating Temperature
Range
Storage Temperature Range
Pin Soldering Temperature
Input/Output Isolation Test Voltage
Pole-to-Pole Isolation Voltage*
(S1 to S2)
LED Continuous Forward Current
LED Reverse Voltage
dc or Peak ac Load Voltage
Continuous dc Load Current
(Form C operation)
Peak Load Current
Output Power Dissipation
(continuous)
TA
Tstg
TS
VISO
—
IF
VR
VL
IL
IP
PDISS
—
—
t=10 s max
t=1 s
IISO=10 µA max
Dry air, dust free,
at sea level
—
IR ≤ 10 µA
IL ≤ 50 µA
—
t=100 ms
Form A
(single shot) Form B
—
–40 to +85 –40 to +85
–40 to +150
260
5300
–40 to +150
260
5300
1600
1600
50
50
8
8
350
200
150
200
†
†
400
600
600
600
* Breakdown occurs between the output pins external to the package.
† Refer to Current-Limit Performance application note for a discussion on relay operation during transient currents.
Units
°C
°C
°C
Vrms
V
mA
V
V
mA
mA
mA
mW
Recommended Operating Conditions
150
IFON =
5 mA to 20 mA
120
90
IFON = 2 mA
60
IFON = 3 mA
IFON = 4 mA
30
LH1502
FORM A
0
–40 –20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
200
160
IFON/OFF =
5 mA to 20 mA
150
IFOFF =
5 mA to 20 mA
120
90
IFOFF = 2 mA
60
IFOFF = 3 mA
IFOFF = 4 mA
30
LH1502
FORM B
0
–40 –20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
120
80
IFON/OFF = 2 mA
IFON/OFF = 3 mA
IFON/OFF = 4 mA
40
LH1512
0
–40 –20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
6G–46
LH1502, LH1512