MCH12140, MCK12140
Table 4. MAXIMUM RATINGS
Symbol
Rating
Value
Unit
VEE
Power Supply (VCC = 0 V)
VI
Input Voltage (VCC = 0 V)
Iout
Output Current
Continuous
Surge
−8.0 to 0
0 to −6.0
50
100
VDC
VDC
mA
TA
Operating Temperature Range
−40 to +70
°C
VEE
Operating Range (Note 3)
−5.7 to −4.2
V
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
NOTE: ESD data available upon request.
1. 10H circuits are designed to meet the DC specifications shown in the table after thermal equilibrium has been established. The circuit is in
a test socket or mounted on a printed circuit board and transverse airflow greater than 500 lfpm is maintained. Outputs are terminated through
a 50 W resistor to −2.0 V except where otherwise specified on the individual data sheets.
2. This table replaces the three tables traditionally seen in ECL 100 K data books. The same DC parameter values at VEE = −4.5 V now apply
across the full VEE range of −4.2 V to −5.5 V. Outputs are terminated through a 50 W resistor to −2.0 V except where otherwise specified
on the individual data sheets.
3. Parametric values specified at: H−Series: −4.20 V to −5.50 V
K−Series: −4.94 V to −5.50 V
Table 5. DC CHARACTERISTICS (VEE = VEE(min) − VEE(max); VCC = GND, unless otherwise noted.)
−40°C
0°C
25°C
70°C
Symbol
Characteristic
Min Typ Max Min Typ Max Min Typ Max Min Typ Max Unit
IEE
Power Supply Current H −
K−
45 −
45 −
38 45 52 38 45 52 38 45 52 mA
38 45 52 38 45 52 42 50 58
VEE Power Supply Voltage H −4.75 −5.2 −5.5 −4.75 −5.2 −5.5 −4.75 −5.2 −5.5 −4.75 −5.2 −5.5 V
K −4.20 −4.5 −5.5 −4.20 −4.5 −5.5 −4.20 −4.5 −5.5 −4.20 −4.5 −5.5
IIH
Input HIGH Current
−
− 150 −
− 150 −
− 150 −
− 150 mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
Table 6. AC CHARACTERISTICS (VEE = VEE(min) − VEE(max); VCC = GND, unless otherwise noted.)
−40°C
0°C
25°C
70°C
Symbol
Characteristic
Min Typ Max Min Typ Max Min Typ Max Min Typ Max Unit
FMAX Maximum Toggle Frequency
− 800 − 650 800 − 650 800 − 650 800 −
−
tPLH Propagation Delay−to−Output
ps
tPHL
R, V to D, U 250 375 500 250 375 500 250 375 500 250 375 500
tr
Output Rise/Fall Times
ps
tf
Q (20 to 80%) − 225 − 100 225 350 100 225 350 100 225 350
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
http://onsemi.com
3