3. MLX90255BC Electrical Specifications
DC Operating Parameters TA = -40oC to 125oC, VDD = 4.5V to 5.5V (unless otherwise specified)
Parameter
Symbol Test Conditions
Min Typ Max Units
Supply voltage
Input voltage
High-level input voltage
Low-level input voltage
Hysteresis on SI and CLK
Wavelength of light source
Clock frequency
Sensor integration time below
60°C (1)
Sensor integration time (full
temperature range) (2)
Pixel charge transfer time (full
temp range)
Setup time, serial input
Hold time, serial input (3)
Operating free-air temperature
Clock pulse duration (high)
Clock pulse duration (low)
Vdd
Vi
Vih
Vil
Fclock
Tint
Tint
Tqt
Tsu(SI)
Th(SI)
Ta
Tw(H)
Tw(L)
4.5
5
5.5
V
0
Vdd
V
Vdd*0.7
Vdd
V
0
Vdd*0.3
V
0.2 0.4 0.8
V
400
1000
nm
64
800
kHz
0.125
100
ms
0.125
2
ms
8
µs
350
ns
160
ns
-40
125
°C
625
ns
625
ns
Notes:
(1) Reset until clock pulse 18 (on declining flank).
Minimum integration time = (133-18) * CLK period + 10µs (this is the time the S&H cap needs to follow).
At 1MHz clock speed, the minimum integration time becomes 0.125ms.
(2) At 125°C, the integration time should be limited to 2ms.
(3) The SI pulse must go low before the rising edge of the next clock pulse.
390109025503
Rev. 001
Page 3 of 12