Electrical Characteristics: (At Maximum Ratings, TA = +25°C unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Peak Off–State Current
Maximum On–State Voltage
IDROM
VT
Gate Open, IT = 100A (Peak)
IT = 100A (Peak)
– – 4 mA
– – 2.5 V
DC Holding Current
Critical Rate–of–Rise of Off–State Voltage
Critical Rate–of–Rise of Commutation
IH
Gate Open
Critical
dv/dt
Gate Open, VD = Rated VDROM,
TC = +100°C
Commutating Gate Open, VD = Rated VDROM,
dv/dt
IT = 25A, TC = +75°C
– – 60 mA
– 40 – V/µs
– 3 – V/µs
DC Gate Trigger Current
MT2 (+), Gate (+); MT2 (–), Gate (–)
MT2 (+), Gate (–); MT2 (–), Gate (+)
DC Gate Trigger Voltage
Gate–Controlled Turn–On Time
IGT
VD = 24V, RL = 12Ω
– – 100 mA
– – 150 mA
VGT
VD = 24V, RL = 12Ω
– – 2.5 V
tgt
VD = Rated VDROM, IGT = 300mA, – 3 – µs
tr = 0.1µs, It = 10A(Peak)
.562
(14.28)
Max
Gate
.1.193
(30.33)
Max
.453
(111.5)
Max
MT1
.200 (5.08) Max
MT2
1/4–28 UNF–2A