A8 - OUTPUT OVERLOAD AND SHORT CIRCUIT
PROTECTION
To prevent permanent damage to the GS-D500A,
three protections have been implemented against
overload and short circuits between:
- output to output
- output to ground
When one of these adverse conditions occurs, the
driver of the output H-bridges is disabled for about
500ms and the condition is signaled by the FAULT
signal.
A9 - FAULT SIGNAL
The FAULT signal is available at pin J3-13. When a
fault is present, pin 13 goes low versus pins 6,7.
Whenever the FAULT signal is activated, the led
provided in the front edge of the module is switched
ON.
The FAULT signal is active (low) when:
- the supply voltage is lower than 12V
- the heatsink temperature is higher than 90°C
- an output overload is present
- a disable is active.
Figure 9 - FAULT signal output circuit
9/10