TYPICAL PERFORMANCE CURVES (TA = 25 °C)
OFF-STATE LEAKAGE CURRENT vs.
APPLIED VOLTAGE
10-5
IF = 0 mA (N.O.)
IF = 10 mA (N.C.)
10-6
TA = 80°C
N.O., N.C.
10-7
10-8
10-9
0
TA = 25°C
N.O., N.C.
100
200
300
400
500
Applied Voltage, VD (V)
TURN-ON TIME vs. FORWARD CURRENT
1.2
VO = 5 V
1.0
0.8
N.O.
0.6
0.4
0.2
0
0
N.C.
5
10
15
20
25
30
Forward Current, IF (mA)
NORMALIZED TURN-ON TIME
vs. AMBIENT TEMPERATURE
3.0
Normalized to 1.0
at TA = 25°C
IF = 10 mA
2.5
VO = 5 V
2.0
N.O.
1.5
1.0
N.C.
0.5
0.0
-25
0
25
50
75
100
Ambient Temperature, TA (°C)
PS7142-1C, PS7142L-1C
LOAD CURRENT vs. LOAD VOLTAGE
200
IF = 0 mA
100
-4.0
-2.0
0
2.0
4.0
-100
-200
Load Voltage, VL (V)
TURN-OFF TIME vs. FORWARD CURRENT
3.0
VO = 5 V
2.5
2.0
N.C.
1.5
1.0
0.5
0
0
N.O.
5
10
15
20
25
30
Forward Current, IF (mA)
NORMALIZED TURN-OFF TIME
vs. AMBIENT TEMPERATURE
3.0
Normalized to 1.0
at TA = 25°C.
2.5
IF = 10 mA
VO = 5 V
2.0
N.C.
1.5
N.O.
1.0
0.5
0.0
-25
0
25
50
75
100
Ambient Temperature, TA (°C)