Only One Name Means ProTek’Tion™
application information
GND
SOLDER PAD
1
4
1
4
2
3
2
3
USB
D+
IC
D-
figure 1 - USB Protection
Two PSLCxx (Unidirectional) in a Common-Mode configuration. Circuit connectivity is as follows:
• Device 1: Line 1(D+) is connected to pins 2 and 3.
• Device 2: Line 2(D-) is connected to pins 2 and 3.
• Device 1 and 2: Pins 1 and 4 connected to ground
PSLC03 - PSLC24C
R
X
1
4
R
R
2
3
T
X
figure 2 - ethernet protection
One PSLCxxC (Bidirectional) in a Differential-Mode configuration. Circuit connectivity is as follow:
• Line 1 (RX) is connected to pins 1 and 4.
• Line 2 (TX) is connected to pins 2 and 3.
circuit board recommendations
Circuit board layout is critical for electromagnetic compatibility protection. The following guidelines are recommended:
• The protection device should be placed near the input terminals or connectors, the device will divert the transient current
immediately before it can be coupled into the nearby traces.
• The path length between the TVS device and the protected line should be minimized.
• All conductive loops including power and ground loops should be minimized.
• The transient current return path to ground should be kept as short as possible to reduce parasitic inductance.
• Ground planes should be used whenever possible. For multilayer PCBs, use ground vias.
05091.R15 8/10