DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

SY100E116JITR View Datasheet(PDF) - Micrel

Part Name
Description
Manufacturer
SY100E116JITR Datasheet PDF : 4 Pages
1 2 3 4
Micrel, Inc.
LOGIC EQUATION
Qn = Dn
SY10E116
SY100E116
DC ELECTRICAL CHARACTERISTICS
VEE = VEE(Min.) to VEE(Max.); VCC = VCCO = GND
TA = –40°C
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
VBB
Output Reference
V
Voltage
10E 1.43 — –1.30 1.38 — –1.27 1.35 — –1.25 1.31 — –1.19
100E 1.43 — –1.26 1.38 — –1.26 1.38 — –1.26 1.38 — –1.26
IIH
Input HIGH Current
— — 200 — — 200 — — 200 — — 200 µA
IEE
Power Supply Current
mA
10E 29 35
29 35
29 35
29 35
100E 29 35
29 35
29 35
33 40
VPP (DC) Input Sensitivity(1)
150 — — 150 — — 150 — — 150 — — mV
VCMR Common Mode Range(2) 2.0 — –0.6 2.0 — –0.6 2.0 — –0.6 2.0 — –0.6 V
Notes:
1. VPP is the minimum differential input voltage required to assure full ECL levels are present at the outputs.
2. VCMR is referenced to the most positive side of the differential input signal. Normal operation is obtained when the "HIGH" input is within the VCMR range
and the input swing is greater than VPP (min.) and <1V.
AC ELECTRICAL CHARACTERISTICS
VEE = VEE(Min.) to VEE(Max.); VCC = VCCO = GND
TA = –40°C
Symbol
Parameter
Min. Typ. Max.
tPD
Propagation Delay to
Output
D 150 300 500
D (S.E.) 150 300 550
VPP (DC) Input Sensitivity(1)
150 150
tskew
Within-Device Skew(2)
Dn to Qn, Qn
50
tskew
Duty Cycle Skew(3)
tPLH tPHL
±10
tr
Rise/Fall Time
tf
20% to 80%
250 375 625
TA = 0°C
Min. Typ. Max.
200 300 450
150 300 500
150 — —
50
±10
275 375 575
TA = +25°C
Min. Typ. Max.
200 300 450
150 300 500
150 — —
50
±10
275 375 575
TA = +85°C
Min. Typ. Max.
200 300 450
150 300 500
150 — —
50
Unit
ps
mV
ps
±10 ps
275 375 575 ps
Notes:
1. Minimum input swing for which AC parameters are guaranteed.
2. Within-device skew is defined as identical transitions on similar paths through a device.
3. Duty cycle skew is defined only for differential operation when the delays are measured from the cross point of the inputs to the cross point of the
outputs.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
3

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]