TA1284FN
TEST CONDITIONS
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
Note 8:
Note 9:
Conversion Gain
fRF input level = −30 dBmW
Noise Figure
Noise Figure meter used.
IF Out Power Level
Measure IF output level when it is maximum level.
Conversion Gain Shift
The Conversion gain shift is defined as a change in conversion gain when supply voltage varies from
VCC = 5 to 4.5 V or from VCC = 5 to 5.5 V.
Frequency Shift
The frequency shift is defined as a change in oscillator frequency when the supply voltage varies
from VCC = 5 to 4.5 V or from VCC = 5 to 5.5 V.
Switching On Drift
Measure frequency change from 2 seconds after switching on to 3 minutes.
1% Cross Modulation
· fd = fp (fdRF input level = −30 dBmW)
· fud = fp+12 MHz 100 kHz, 30%AM
Input two signals, and increase the fudRF input level.
Measure the fudRF input level when the suppression level reaches 56.5 dB.
Inter Modulation
· fd = fp
· fud = fp+1 MHz
Input the two signals above, and increase the input levels.
When the IF output level is −11 dBmW, measure the suppression level.
Phase Noise (10 kHz offset)
Measure phase noise of 10 kHz offset.
2003-02-06 6/9