Table 10. Fault Detection
Root Cause
Signal
Effect
Test detect
Alternator belt breaking
P
Alternator disexcitation VP<VPHH1 & VB+<Vreg
Brushes open
P
Alternator disexcitation VP<VPHH1 & VB+<Vreg
Field Driver Open
P
Alternator disexcitation VP<VPHH1 & VB+<Vreg
Field interruption
P
Alternator disexcitation VP<VPHH1 & VB+<Vreg
Field short circuit to the battery
F+
Overvoltage
VF+>VS1 & VB+ > Vov-d
Field short circuit to the ground
P
Alternator disexcitation VP<VPHH1 & VB+<Vreg
Battery discharge
B+
Undervoltage
VB+<Vuv
The diagnostic result is disabled during the Soft-start delay time t_ST 0...3 and the soft-start / soft attack timing t_SL 0...3