RATINGS AND CHARACTERISTIC CURVES
TEST CIRCUIT 3 FOR IH PARAMETERS:
SMTPAxxx
R
VBAT=-48V
D.U.T.
Surge generator
This is a GO-NO GO Test w hich allow s to confirm the holding current (IH) level in a functional test circuit.
TESTPROCEDURE :
1) Adjust the current level at the IH value by short circuiting the AK of the D.U.T.
2) Fire the D.U.T w ith a surge current : Ipp = 10A , 10/1000 ms.
3) The D.U.T w ill come back off-state w ithin 50ms max.
PACKAGE MECHANICAL DATA
SMB(JEDEC DO-214AA)
E1
E
L
b
FOOT PRINT in millimeters (inches)
REF.
A1
A2
b
c
E
E1
D
L
DIMENSIONS
MILLIMETERS INCHES
MIN. MAX. MIN. MAX.
1.9 2.45 0.075 0.096
0.05 0.2 0.002 0.008
1.95 2.2 0.077 0.087
0.15 0.41 0.006 0.016
5.1 5.6 0.201 0.22
4.05 4.6 0.159 0.181
3.3 3.95 0.13 0.156
0.75 1.6 0.03 0.063
1.52(0.059)
2.75(0.108)
Document Number 0286002
1.52(0.059)
BLGALAXY ELECTRICAL
www.galaxycn.com
4.