P2820, P2821, P2822, P2823
SPECIFICATIONS
Distortion
Exceed requirements of EN 50065-1 (1991) for
conducted emissions
Conditions:
P2820, Fundamental 40-90kHz into artificial mains
network of EN 50065-1 at 122dBµV and AC
magnetizing current of 40mA rms at 50Hz. Circuit
as Figure 1.
P2822, Fundamental 125-140kHz into artificial
mains network of EN 50065-1 at 116dBμV and AC
magnetizing current of 3mA rms at 50Hz. Circuit as
Figure 3.
P2821, Fundamental 95-125kHz into artificial mains
network of EN 50065-1 at 116dBμV and AC
magnetizing current of 10mA rms at 50Hz. Circuit
as Figure 2.
P2823, Fundamental 140-148.5kHz into artificial
mains network of EN 50065-1 at 116dBμV and AC
magnetizing current of 3mA rms at 50Hz. Circuit as
Figure 4.
ETALDOC 345/10
Page 2 of 6
March 2006