Data Sheet
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 5.
Parameter
VDD to GND
VLOGIC to GND
VOUT to GND
VREF to GND
Digital Input Voltage to GND1
SDA and SCL to GND
Operating Temperature Range
Storage Temperature Range
Junction Temperature
Reflow Soldering Peak Temperature,
Pb Free (J-STD-020)
ESD
Human Body Model (HBM)
Field-Induced Charged Device
Model (FICDM)
Rating
−0.3 V to +7 V
−0.3 V to +7 V
−0.3 V to VDD + 0.3 V
−0.3 V to VDD + 0.3 V
−0.3 V to VLOGIC + 0.3 V
−0.3 V to +7 V
−40°C to +105°C
−65°C to +150°C
125°C
260°C
3.5 kV
1.5 kV
1 Excluding SDA and SCL.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
AD5696/AD5694
THERMAL RESISTANCE
θJA is specified for the worst-case conditions, that is, a device
soldered in a circuit board for surface-mount packages. This
value was measured using a JEDEC standard 4-layer board with
zero airflow. For the LFCSP package, the exposed pad must be
tied to GND.
Table 6. Thermal Resistance
Package Type
θJA
16-Lead LFCSP
70
16-Lead TSSOP
112.6
Unit
°C/W
°C/W
ESD CAUTION