Approval sheet
General Purpose Capacitors
No.
Item
13. Humidity (Damp
Heat) Steady State
Test Condition
Requirements
* Test temp.: 40±2°C
* Humidity: 90~95% RH
* Test time: 500+24/-0hrs.
* Measurement to be made after keeping at room temp.
for 24±2 hrs. (Class I) or 48±4 hrs. (Class II).
* No remarkable damage.
* Cap change:
NP0: within ±5% or 0.5pF whichever is larger
X7R, X5R: ≥10V, within ±12.5%; 6.3V, within ±25%
Y5V: ≥10V, within ±30%; 6.3V, within +30/-40%
* Q/D.F. value:
NP0: More than 30pF Q≥350, 10pF≤C≤30pF, Q≥275+2.5C
Less than 10pF Q≥200+10C
X7R, X5R:
Rated
vol.
D.F.≦ Exception of D.F.≦
≧50V 3%
6%
0603≧0.047µF; 0805≧0.18µF;
1206≧0.47µF
10% 0805≧1µF; 1210≧10µF
25V 5% 14% 0603≧0.33µF;1206≧4.7µF
15%
0402≧0.10µF; 0603≧0.47µF; 0805≧2.2µF;
1206≧6.8µF
16V
5%
10%
0603≧0.15µF; 0805≧0.68µF;
1206≧2.2µF; 1210≧4.7µF,
15%
0402≧0.033µF; 0603≧0.68µF;0805≧2.2µF
1206≧4.7µF; 1210≧22µF
10V
7.5%
15%
0402≧0.33µF; 0603≧0.33µF;0805≧2.2µF
1206≧2.2µF; 1210≧22µF
20% 0201≧0.1µF ;0402≧1µF
6.3V
15%
30%
0402≧2.2µF ;0603≧10µF; 0805≧4.7µF;
1206≧47µF;1210≧100µF
Y5V:
Rated vol.
≧ 50V
35V
25V
16V
(C<1.0µF)
16V
(C≧1.0µF)
10V
6.3V
D.F.≦
7.5%
10%
7.5%
10%
12.5%
20%
30%
Exception of D.F.≦
10%
0603≧0.1µF; 0805≧0.47µF;
1206≧4.7µF
---
---
10%
0402≧0.047µF;0603≧0.1µF;
0805≧0.33µF;1206≧1µF;
1210≧4.7µF
15%
0402≧0.068µF;0603≧0.47µF;
1206≧4.7µF; 1210≧22µF
12.5% 0402≧0.068µF; 0603≧0.68µF
20% 0402≧0.22µF
0603≧2.2µF; 0805≧3.3µF;
20% 1206≧10µF;1210≧22µF;
1812≧47µF;
30% 0402≧0.47µF
---
---
*I.R.: ≥10V, 1GΩ or 50 Ω-F whichever is smaller.
Class II (X7R, X5R, Y5V)
Rated voltage
100V: X7R
16V:0402≥0.22µF
10V:0201≥47nF;0402≥0.47µF;0603≥0.47µF
; 0805≥2.2µF;1206≥4.7µF;1210≥47µF
6.3V
Insulation
Resistance
1GΩ or
RxC≧10 Ω-F
whichever is
smaller.
Page 11 of 16
ASC_General Purpose_001M_DS-IBD