KA78XXE/KA78XXAE
Electrical Characteristics (KA7824AE) (Continued)
(Refer to the test circuits. 0°C < TJ < +125°C, Io =1A, V I = 33V, C I=0.33µF, CO=0.1µF, unless otherwise specified)
Parameter
Output Voltage
Line Regulation (Note1)
Load Regulation (Note1)
Quiescent Current
Quiescent Current Change
Output Voltage Drift (Note2)
Output Noise Voltage
Ripple Rejection (Note2)
Dropout Voltage
Output Resistance (Note2)
Short Circuit Current
Peak Current (Note2)
Symbol
VO
Regline
Regload
IQ
∆IQ
∆V/∆T
VN
RR
VDrop
rO
ISC
IPK
Conditions
TJ =+25°C
IO = 5mA to 1A, PO ≤15W
VI = 27.3V to 38V
VI= 27V to 38V, IO = 500mA
VI= 21V to 33V
TJ =+25°C
VI= 26.7V to 38V
VI= 30V to 36V
TJ =+25°C, IO = 5mA to 1.5A
IO = 5mA to 1.0A
IO = 250mA to 750mA
TJ =+25°C
VI = 27.3V to 38V, TJ =+25°C
VI = 27.3V to 38V, IO = 500mA
IO = 5mA to 1.0A
IO = 5mA
f = 10Hz to 100kHz, TA = 25°C
f = 120Hz, IO = 500mA
VI = 28V to 38V
IO = 1A, TJ =+25°C
f = 1kHz
VI= 35V, TA =+25°C
TJ=+25°C
Min. Typ. Max. Unit
23.5 24 24.5
V
23 24 25
-
18 240
-
6 240
mV
-
18 240
-
6 120
-
15 100
-
15 100 mV
-
7
50
-
5.2 6.0
mA
-
-
0.8
-
-
0.8 mA
-
-
0.5
-
-1.5
- mV/°C
-
10
- µV/Vo
-
54
-
dB
-
2.0
-
V
-
20
-
mΩ
-
250
-
mA
-
2.2
-
A
Note:
1. Load and line regulation are specified at constant junction temperature. Change in VO due to heating effects must be taken
into account separately. Pulse testing with low duty is used.
2. These parameters, although guaranteed, are not 100% tested in production.
17