Fiber Optic Transmitter
MOF-T3C5
Fig. 1 Measuring Method of Optical Output Coupling with Fiber
MOF-T3C5
Unit to be measured
Standard optical fiber cable
Optical power meter
Vin
VCC
GND
The optical power meter must be calibrated
to have the wavelength sensitivity of 660 nm.
( 0dBm=1mW )
D
VCC
Notes (1)Vcc=5.0V (State of operating)
(2)To bundle up the standard fiber optic cable, make it into a loop with the diameter D=10cm or more.
Fig. 2 Measuring Method of Intput Voltage and Supply Current
MOF-T3C5
Unit to be measured
Standard optical fiber cable
Vin
VCC
GND
Vin
Icc
The optical power meter must be calibrated
to have the wavelength sensitivity of 660 nm.
( 0dBm=1mW )
VCC
Input conditions and judgement method
Conditions
Vin=2.1V or more
Vin=0.8V or less
Judgement method
-21dBm<=Pc<=-15dBm, Icc=13mA or less
Pc<=-36dBm, Icc=13mA or less
Note: Vcc=5.0V (State of operating)
Unity Opto Technology Co., Ltd.
3/4
REV : A2