DATA SHEET
AAT1147
High Efficiency, Low Noise, Fast Transient 400mA Step-Down Converter
Electrical Characteristics1
TA = -40°C to +85°C, unless otherwise noted. Typical values are TA = 25°C, VIN = 3.6V.
Symbol Description
Step-Down Converter
VIN
Input Voltage
VUVLO
UVLO Threshold
VOUT
VOUT
IQ
ISHDN
ILIM
RDS(ON)H
RDS(ON)L
ILXLEAK
VLINEREG
VOUT
IOUT
TS
FOSC
TSD
THYS
EN
VEN(L)
VEN(H)
IEN
Output Voltage Tolerance
Output Voltage Range
Quiescent Current
Shutdown Current
P-Channel Current Limit
High Side Switch On Resistance
Low Side Switch On Resistance
LX Leakage Current
Line Regulation
Out Threshold Voltage Accuracy
Out Leakage Current
Start-Up Time
Oscillator Frequency
Over-Temperature Shutdown Threshold
Over-Temperature Shutdown Hysteresis
Enable Threshold Low
Enable Threshold High
Input Low Current
Conditions
VIN Rising
Hysteresis
VIN Falling
IOUT = 0 to 400mA, VIN = 2.7V to 5.5V
No Load
EN = AGND = PGND
VIN = 5.5V, VLX = 0 to VIN, EN = GND
VIN = 2.7V to 5.5V
0.6V Output, No Load, TA = 25°C
0.6V Output
From Enable to Output Regulation
VIN = VOUT = 5.5V
Min
2.7
1.8
-3.0
0.6
600
591
1.0
1.4
-1.0
Typ Max Units
5.5
2.7
100
160
3.0
VIN
300
1.0
0.45
0.40
1
0.1
600 609
0.2
150
1.4
2.0
140
15
0.6
1.0
V
V
mV
V
%
V
μA
μA
mA
μA
%/V
mV
μA
μs
MHz
°C
°C
V
V
μA
1. The AAT1147 is guaranteed to meet performance specifications over the -40°C to +85°C operating temperature range and is assured by design, characterization, and correla-
tion with statistical process controls.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
4
201986A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • May 23, 2012