SHARP CORPORATION
ED-96027A
MODEL No.
PC3H4
1 September 30, 1999
PAG E
Attach
sheet- 1- 1
Precautions for Photocouplers
1 For cleaning
I
( 1) Solvent cleaning : Solvent temperature 45°C or less
Immersion for 3 mm or less
(2) Ultrasonic
cleaning
: The effect to device by ultrasonic cleaning differs
by cleaning bath size, ultrasonic power
output, cleaning time, PCB size or device mounting
condition etc. Please test it in actual using condition
and confirm that doesn’t occur any defect before starting
the ultrasonic cleaning.
(31 Applicable solvent : Ethyl alcohol, Methyl alcohol, Isopropyl alcohol
In case when the other solvent is used, there are cases that
the packaging resin is eroded. Please use the other solvent
after thorough confirmation is performed in actual using condition.
2. The LED used in the Photocoupler generally decreases the light emission power
by operation. In case of long operation time, please design the circuit with considering
the degradation of the light emission power of the LED. (50%/5years)
3. There are cases that the deviation of the CTR and the degradation
of the LED become big at IF is less than 1 .OmA.
Please design the circuit with considering this point.
of the light emission
power