DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CMX813 View Datasheet(PDF) - MX-COM Inc

Part Name
Description
Manufacturer
CMX813 Datasheet PDF : 19 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
CMX813 Multi-Standard Analog Paging Decoder
6
5. Software Description
CMX813 Advance Information
5.1 Address/Commands
Instructions and data are transferred, via C-BUS, in accordance with the timing information provided in
Figure 3.
Instruction and data transactions to and from the CMX813 consist of an Address/Command (A/C) byte, which
may be followed by either:
(i)
a further instruction or data (1 byte) or
(ii) a status or Rx data reply (1 byte)
5.1.1 8-bit Write Only Registers
HEX
ADDRESS/
COMMAND
$01
REGISTER
NAME
GENERAL
RESET
$30
CONTROL
$31
TONE
ADDRESS
BIT 7
(D7)
BIT 6
(D6)
N/A
N/A
ROM PAGE SELECT
MSB
LSB
BIT 7
BIT 6
MSB
BIT 7
BIT6
BIT 5
(D5)
BIT 4
(D4)
BIT 3
(D3)
BIT 2
(D2)
N/A
N/A
N/A
N/A
DECODER BANDWIDTH
MSB
LSB
BIT 5 BIT 4 BIT 3 BIT 2
TONE ADDRESS
BIT 5 BIT 4 BIT 3 BIT 2
BIT 1
(D1)
BIT 0
(D0)
N/A
N/A
OPERATION MODE
MSB
LSB
BIT 1
BIT 0
BIT 1
LSB
BIT 0
5.1.2 Write Only Register Description
5.1.2.1 GENERAL RESET (Hex address $01)
The reset command has no data attached to it. It sets the device (write) registers to zero and enters the Zero
Power mode. And all RAM contents and RAM FULL bit of the STATUS Register are reset to 0.
5.1.2.2 CONTROL Register (Hex address $30)
This register is used to control the functions of the device as described below:
ROM PAGE SELECT
(Bits 7 and 6)
DECODER BANDWIDTH
(Bits 5, 4, 3 and 2)
OPERATION MODE
(Bits 1 and 0)
These two bits select the section of the ROM where pre-programmed tone
data are stored for detection. The ROM area is divided into three sections
(pages). The 1 tone or 2 tone system tones are stored in ROM Page 1 and 2.
The 5/6 tone and HSC tones are stored in ROM Page 3.
These four bits set the bandwidth of the tone decoder according to table
below:
These two bits select the mode of operation of the device.
Bit 7
0
0
1
1
Bit 6
0
1
0
1
ROM PAGE
No ROM PAGE selected, a valid but unrecognized tone may be detected,
no interrupt generated
ROM Page 1 selected, for 1 tone or 2 tone system
ROM Page 2 selected, for 1 tone or 2 tone system
ROM Page 3 selected, for 5/6 tone or HSC tone system
Table 3: ROM PAGE SELECT (Bits 7 and 6)
¤2000 MX-COM, Inc.
www.mxcom.com tel: 336 744 5050 800 638 5577 fax: 336 744 5054
Doc. # 20480220.002
4800 Bethania Station Road, Winston-Salem, NC 27105-1201, USA All trademarks and service marks are held by their respective customers.

Share Link: 