TP8452
PS/2 2D 3Key Mouse
Controller
Function Descriptions
(1) PS/2 Mouse Mode
(A) Operating mode
There are four operating modes in PS/2 mouse :
a. Reset Mode :
In this mode a self-test is initiated during power-on or by a Reset command. After reset
signal, PS/2 mouse will send:
(a) Completion code AA & ID code 00.
(b) Set default:
sampling rate: 100 reports/s
non-autospeed
stream mode
4 counts/mm
disable
b. Stream Mode:
The maximum rate of transfer is the programmed sampling rate.
Data report is transmitted if
(a) switch is pressed
(b) movement has been detected
c. Remote Mode:
Data is transmitted only in response to a Read Data command.
d. Wrap Mode:
Any byte of data sent by the system, except hex EC ( Reset wrap mode ) or hex FF ( Reset
), is returned by TP8452.
Page 8 of 20
TOPRO CONFIDNETIAL
2003/7/31 Print