MAX809 Series, MAX810 Series
ELECTRICAL CHARACTERISTICS (continued) TA = −40°C to +105°C unless otherwise noted. Typical values are at
TA = +25°C. (Note 5)
Characteristic
Symbol
Min
Typ
Max
Detector Voltage Threshold Temperature Coefficient
−
30
−
VCC to Reset Delay VCC = VTH to (VTH − 100 mV)
Reset Active TimeOut Period (Note 6)
MAX8xxSN(Q)293D1
MAX8xxSN(Q)293D2
MAX8xxSN(Q)293D3
MAX8xxSN(Q)293
−
10
−
tRP
1.0
−
3.3
20
−
66
100
−
330
140
−
460
RESET Output Voltage Low (No Load) (MAX809)
VCC = VTH − 0.2 V
1.6 V v VTH v 2.0 V, ISINK = 0.5 mA
2.1 V v VTH v 4.0 V, ISINK = 1.2 mA
4.1 V v VTH v 4.9 V, ISINK = 3.2 mA
VOL
−
−
0.3
RESET Output Voltage High (No Load) (MAX809)
VCC = VTH + 0.2 V
1.6 V v VTH v 2.4 V, ISOURCE = 200 mA
2.5 V v VTH v 4.9 V, ISOURCE = 500 mA
VOH
0.8 VCC
−
−
RESET Output Voltage High (No Load) (MAX810)
VCC = VTH − 0.2 V
1.6 V v VTH v 2.4 V, ISOURCE = 200 mA
2.5 V v VTH v 4.9 V, ISOURCE = 500 mA
VOH
0.8 VCC
−
−
RESET Output Voltage Low (No Load) (MAX810)
VCC = VTH + 0.2 V
1.6 V v VTH v 2.0 V, ISINK = 0.5 mA
2.1 V v VTH v 4.0 V, ISINK = 1.2 mA
4.1 V v VTH v 4.9 V, ISINK = 3.2 mA
VOL
−
−
0.3
5. Production testing done at TA = 25°C, over temperature limits guaranteed by design.
6. Contact your ON Semiconductor sales representative for timeout options availability for other threshold voltage options.
Unit
ppm/°C
msec
msec
V
V
V
V
http://onsemi.com
5