DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MT48LC16M16A2BG(2005) Ver la hoja de datos (PDF) - Micron Technology

Número de pieza
componentes Descripción
Fabricante
MT48LC16M16A2BG
(Rev.:2005)
Micron
Micron Technology 
MT48LC16M16A2BG Datasheet PDF : 61 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
256Mb: x4, x8, x16
SDRAM
COMMAND INHIBIT
The COMMAND INHIBIT function prevents new
commands from being executed by the SDRAM, re-
gardless of whether the CLK signal is enabled. The
SDRAM is effectively deselected. Operations already
in progress are not affected.
NO OPERATION (NOP)
The NO OPERATION (NOP) command is used to
perform a NOP to an SDRAM which is selected (CS# is
LOW). This prevents unwanted commands from being
registered during idle or wait states. Operations already
in progress are not affected.
LOAD MODE REGISTER
The mode register is loaded via inputs A0–A11 (A12
should be driven LOW.) See mode register heading in
the Register Definition section. The LOAD MODE REG-
ISTER command can only be issued when all banks are
idle, and a subsequent executable command cannot
be issued until tMRD is met.
ACTIVE
The ACTIVE command is used to open (or activate)
a row in a particular bank for a subsequent access. The
value on the BA0, BA1 inputs selects the bank, and the
address provided on inputs A0-A12 selects the row.
This row remains active (or open) for accesses until a
PRECHARGE command is issued to that bank. A
PRECHARGE command must be issued before open-
ing a different row in the same bank.
READ
The READ command is used to initiate a burst read
access to an active row. The value on the BA0, BA1
inputs selects the bank, and the address provided on
inputs A0-A9, A11 (x4), A0-A9 (x8), or A0-A8 (x16) se-
lects the starting column location. The value on input
A10 determines whether or not auto precharge is used.
If auto precharge is selected, the row being accessed
will be precharged at the end of the READ burst; if auto
precharge is not selected, the row will remain open for
subsequent accesses. Read data appears on the DQs
subject to the logic level on the DQM inputs two clocks
earlier. If a given DQM signal was registered HIGH, the
corresponding DQs will be High-Z two clocks later; if
the DQM signal was registered LOW, the DQs will pro-
vide valid data.
WRITE
The WRITE command is used to initiate a burst write
access to an active row. The value on the BA0, BA1
inputs selects the bank, and the address provided on
inputs A0-A9; A11 (x4); A0-A9 (x8); or A0-A8 (x16) se-
lects the starting column location. The value on input
A10 determines whether or not auto precharge is used.
If auto precharge is selected, the row being accessed
will be precharged at the end of the WRITE burst; if
auto precharge is not selected, the row will remain open
for subsequent accesses. Input data appearing on the
DQs is written to the memory array subject to the DQM
input logic level appearing coincident with the data. If
a given DQM signal is registered LOW, the correspond-
ing data will be written to memory; if the DQM signal is
registered HIGH, the corresponding data inputs will
be ignored, and a WRITE will not be executed to that
byte/column location.
PRECHARGE
The PRECHARGE command is used to deactivate
the open row in a particular bank or the open row in all
banks. The bank(s) will be available for a subsequent
row access a specified time (tRP) after the PRECHARGE
command is issued. Input A10 determines whether
one or all banks are to be precharged, and in the case
where only one bank is to be precharged, inputs BA0,
BA1 select the bank. Otherwise BA0, BA1 are treated as
“Don’t Care.” Once a bank has been precharged, it is in
the idle state and must be activated prior to any READ
or WRITE commands being issued to that bank.
AUTO PRECHARGE
Auto precharge is a feature which performs the
same individual-bank PRECHARGE function de-
scribed above, without requiring an explicit command.
This is accomplished by using A10 to enable auto
precharge in conjunction with a specific READ or WRITE
command. A PRECHARGE of the bank/row that is ad-
dressed with the READ or WRITE command is auto-
matically performed upon completion of the READ or
WRITE burst, except in the full-page burst mode, where
AUTO PRECHARGE does not apply. Auto precharge is
nonpersistent in that it is either enabled or disabled for
each individual READ or WRITE command.
Auto precharge ensures that the precharge is initi-
ated at the earliest valid stage within a burst. The user
must not issue another command to the same bank
until the precharge time (tRP) is completed. This is
determined as if an explicit PRECHARGE command
was issued at the earliest possible time, as described
for each burst type in the Operation section of this data
sheet.
BURST TERMINATE
The BURST TERMINATE command is used to trun-
cate either fixed-length or full-page bursts. The most
PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8
256MSDRAM.pmd – Rev. H; Pub. 2/05
16
Micron Technology, Inc., reserves the right to change products or specifications without notice.
©2003 Micron Technology, Inc. All rights reserved.

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]