2A 1-Cell Li+ DC-DC Charger for USB*
and Adapter Power
ELECTRICAL CHARACTERISTICS (continued)
(VDC = VUSB = 5V, VBAT = 4V, circuit of Figure 2, TA = -40°C to +85°C, unless otherwise noted. Typical values are at TA = +25°C.)
(Note 1)
PARAMETER
Fast-Charge Current
DONE Threshold
RISET Resistor Range
ISET Output Voltage
ISET Current Monitor Gain
BAT Leakage Current
Charger Soft-Start Time
Charger Thermal Limit
Temperature
Charger Thermal Limit Gain
CHARGER TIMER
Prequalification Time
Fast-Charge Time
Timer Accuracy
Timer Extend Current Threshold
CONDITIONS
RISET = 600Ω
RISET = 1.2kΩ
RISET = 2.4kΩ
Percentage of fast-charge, IBAT decreasing
No DC or USB input
With valid input power, VCEN = 5V
Charge current = 0 at +120°C
CCT = 0.15µF
CCT = 0.15µF
Percentage of fast-charge current below which the timer
clock operates at half-speed
MIN
1800
900
450
0.6
-15
40
TYP
2000
1000
500
10
1.5
1.25
0.05
1
1.0
100
5
33
660
50
MAX
2200
1100
550
2.4
4
6
+15
60
UNITS
mA
%
kΩ
V
mA/A
µA
ms
°C
%/°C
min
min
%
%
Timer Suspend Current Threshold
Percentage of fast-charge current below which timer
clock pauses
16
20
24
%
Charge Done Delay Time
From done threshold detection until charger turns off and
CHG goes high
15
s
THERMISTOR MONITOR
THM Threshold, Hot
When charging is suspended, 1% hysteresis
0.27 x 0.28 x 0.29 x
VVL
VVL
VVL
V
THM Threshold, Cold
When charging is suspended, 1% hysteresis
0.73 x 0.74 x 0.75 x
VVL
VVL
VVL
V
THM Threshold, Disabled
THM function is disabled below this voltage
0.0254 0.03 x 0.036 x
x VVL VVL
VVL
V
THM Input Leakage
THM = GND or VL; TA = +25°C
THM = GND or VL; TA = +85°C
-0.1 +0.001 +0.2
µA
0.01
THERMAL SHUTDOWN, VL, AND LOGIC I/O: CHG, FLT, DOK, UOK, DCM, CEN, USUS, IUSB
Logic-Input Thresholds
(DCM, CEN, USUS, IUSB)
High level
Low level
Hysteresis
1.3
V
0.4
50
mV
Logic-Input Leakage Current
(DCM, CEN, USUS, IUSB)
VINPUT = 0 to 5.5V
TA = +25°C
TA = +85°C
0.001
1
µA
0.01
4 _______________________________________________________________________________________