ACS711
Hall Effect Linear Current Sensor with Overcurrent
Fault Output for < 100 V Isolation Applications
x25AB PERFORMANCE CHARACTERISTICS for for LC package and E Temperature Range1
TA = 25°C and VCC = 3.3 V, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min.
Optimized Accuracy Range
IP
–25
Over full range of IP
–
Sensitivity
Sens Full scale of IP applied for 5 ms, TA = –40°C to 25°C
–
Full scale of IP applied for 5 ms, TA = 25°C to 85°C
–
Noise2
VNOISE TA = 25°C, no external low pass filter on VIOUT
–
VOE(TA) IP = 0 A, TA = 25°C
–
Electrical Offset Voltage
VOE(TOP)HT IP = 0 A, TA = 25°C to 85°C
–
VOE(TOP)LT IP = 0 A, TA = –40°C to 25°C
–
Total Output Error3
ETOT IP =±25 A, TA = –40°C to 85°C
–
1See Characteristic Performance Data for parameter distributions over temperature.
2±3 sigma noise voltage.
3Percentage of IP, with IP = ±25 A.
Typ.
–
55
55
55
8
±5
±30
±35
±4
Max.
25
–
–
–
–
–
–
–
–
Units
A
mV/A
mV/A
mV/A
mV
mV
mV
mV
%
x25AB PERFORMANCE CHARACTERISTICS for LC package and K Temperature Range1
TA = 25°C and VCC = 3.3 V, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min.
Optimized Accuracy Range
IP
–25
Over full range of IP
–
Sensitivity
Sens Full scale of IP applied for 5 ms, TA = –40°C to 25°C
–
Full scale of IP applied for 5 ms, TA = 25°C to 125°C
–
Noise2
VNOISE TA = 25°C, no external low pass filter on VIOUT
–
VOE(TA) IP = 0 A, TA = 25°C
–
Electrical Offset Voltage
VOE(TOP)HT IP = 0 A, TA = 25°C to 125°C
–
VOE(TOP)LT IP = 0 A, TA = –40°C to 25°C
–
Total Output Error3
ETOT IP =±25 A, TA = –40°C to 125°C
–
1See Characteristic Performance Data for parameter distributions over temperature.
2±3 sigma noise voltage.
3Percentage of IP, with IP = ±25 A.
Typ.
–
55
55
55
8
±5
±30
±35
±4
Max.
25
–
–
–
–
–
–
–
–
Units
A
mV/A
mV/A
mV/A
mV
mV
mV
mV
%
Allegro MicroSystems, LLC
6
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com